IBM Worklight 6.0.0.1 - Timeout setting in Adapter

2019-02-15 19:57发布

How can I change the timeout when calling from the application to the adapter using WL.Client.invokeProcedure?

I have read the answer in the following post, but it is not working: How to increase the adapter procedure timeout value in Worklight?

My configuration:

initOptions.js

timeout: 600000


Adapter XML

<procedure name="addInsertarMensaje" securityTest="wl_unprotected" requestTimeoutInSeconds="600">


Adapter invocation

var timeout = 600000;
var invocationOptions = {
  onSuccess: successSynchDoc,
  onFailure: errorSynchDoc,
  invocationContext: context,
  timeout: timeout
};


Android LogCat:

12-02 11:23:04.603: D/Mapfre(21661): MyCustomTrace: Invoking the adapter

12-02 11:23:05.564: D/Mapfre(21661): Request [http://192.168.1.39:10080/xxx/apps/services/api/Mapfre/android/query]

12-02 11:23:26.214: D/Mapfre(21661): MyCustomTrace: After invoking the adapter

12-02 11:24:29.297: E/Mapfre(21661): [http://192.168.1.39:10080/xxx/apps/services/api/Mapfre/android/query] Host is not responsive. Try to manually access the URL through the android emulator browser to verify connectivity.


Is there a max value?

These are the traces in each part.

In the app:

12-02 14:30:24.473: D/Mapfre(8641): Custom Trace. Just befor WL.Client.invokeProcedure
12-02 14:30:25.103: D/Mapfre(8641): Request [http://192.168.1.39:10080/xxx/apps/services/api/Mapfre/android/query]
12-02 14:31:42.670: E/Mapfre(8641): [http://192.168.1.39:10080/xxx/apps/services/api/Mapfre/android/query] Host is not responsive. Try to manually access the URL through the android emulator browser to verify connectivity.

In the adapter receiving the invocation from the app:

[2/12/13 14:31:45:224 CET] 000000bf ht.integration.js.JavaScriptIntegrationLibraryImplementation I Custom Trace. Into Adapter implementation.

In the adapter receiving the answer from the host:

[2/12/13 14:33:34:714 CET] 000000bf ht.integration.js.JavaScriptIntegrationLibraryImplementation I Custom Trace. Received id: 3

1条回答
你好瞎i
2楼-- · 2019-02-15 20:41
  • The application is not calling the adapter. Basic diagram:

Application << >>[ Worklight Server << >> Adapter ]<< >> Backend

  • Also, there is no maximum value Worklight imposes on timeouts. There's a default value, but you have changed it in all 3 locations.

Short explanation:

  1. In initOptions.js, the timeout property relates to the amount of time the app will wait for a connection to the Worklight Server.

  2. In the adapter's XML, the requestTimeoutInSeconds property relates to the amount of time the Worklight Server will wait for a response from the Backend.

  3. In the invocation options, the timeout property relates to the amount of time the app will wait for a response from the Worklight Server.

In your case, the error points that you did not even reach the Worklight Server, let alone invoke the adapter procedure.

  • Verify that your can reach the server; follow the instructions from the error message - try to load Worklight Console in your device's mobile browser
  • Verify the device and server are in the same network
  • Verify the firewall (if enabled) is not blocking any crucial ports or addresses

In case you did reach the Worklight Server, since obviously 600 seconds did not pass, I believe that the host is simply not reachable. Make sure that you are pointing to the correct host address and that nothing is preventing a connection to pass successfully.

If the host was found, and something else is not correct in the path or network, a response will be returned, but it will not wait 600 seconds.