I need to change the value of a volatile parameter over time in a simulation. I.e. in the first 30s
of the simulation I need exp(400ms)
after that, until 60s
I need exp(800ms)
and after 60s exp(2s)
for interArrivalTime
.
相关问题
- Is it possible to use RInside in omnet++/Veins pro
- How to create own header structure in OMNET++
- How to get Coordinates of each vehicle in VEINS?
- Omnet++ , veins , the number of neighbors nodes fo
- How to collect traffic data and macroscopic statis
相关文章
- Wave Service Advertisement (WSA) implementation
- Omnet++ : Ad Hoc Network
- How can I get a traffic light that exists in sumo
- How can I combine my customize module with Omnet++
- Using a subset of a SUMO scenario for OMNeT++ netw
- Transmission of vehicular status in Veins
- Calculating distance between cars nodes VEINS
- How to change configuration of network during simu
For volatile parameters there is a pretty easy trick. Use the
? :
operator along with thesimTime()
NED function:or you can even chain them as ?: operator is evaluated left to right:
would give:
exponential(400ms)
below30s
exponential(800ms)
between30
and60s
exponential(2s)
after60s