How to ignore output from executable with CruiseCo

2020-07-18 07:42发布

问题:

I'm running a little find and replace utility called fart.exe (yes, fart, as in Find and Replace Text) as part of my CC build. Works great.

The problem is that FART while it is working displays a little ASCII spinner composed of pipe, dash, slash... | / - . There isn't a way to suppress this spinner, and CC thinks these little symbols are error messages and the build fails. I've tried:

  • adding those symbols as successexitcodes in CC -- same result, apparently only ints work
  • Calling fart via a batch file with ECHO OFF -- it still outputs the spinner and causes the build to fail

Any other ideas?

<exec>
<executable>C:\fart.exe</executable>
<buildArgs>myfile.txt string1 string2</buildArgs>
<successExitCodes>1,0</successExitCodes>
</exec>

回答1:

I also ran into this issue with fart and a ci system. Rather than recompile the executable, I redirected the output to NUL.

First I determined that the spinner output was on stderr. Then I appended "2>NUL" to the command line which called fart, and it no longer farted a spinner on stderr.

Anybody else getting a pinwheel in a smelly breeze visual from that last sentence?



回答2:

In my case I needed to run fart.exe from a batch file which was run later on by Jenkins, and here is what I found out.

fart.exe returns in %errorlevel% the amount of replacements that are done. If that amount is 1, that will be the value of %errorlevel%, which means having an exit code 1, what will make Jenkins fail.

In order to fix this here is what I added to my batch file:

REM standard "fart.exe" error-handling block; 9009 (missing program) is bad, anything else above 0 is OK and should be reset to 0 for standard handling
if ERRORLEVEL 9009 (
    REM do nothing
) else (
    if ERRORLEVEL 1 CMD /C EXIT 0
)

REM ensure that we exit with the current errorlevel context...
exit %errorlevel%

Adding ECHO OFF to the call of fart.exe made the %errorlevel% value be 0 again, but by doing that the replacements done by fart stopped being successful.

I hope this helps someone!



回答3:

Thanks for the answers, but I ended up doing two things:

  • Recompiled the text replacement app (fart) without the spinner. Even after doing this CC was still failing for some reason, so I...
  • Moved batch executables to the msbuild file instead of cc config file. CC then built successfully.

I'm sure if I understood CC better I could have gone about this better way but for now this does the trick!



回答4:

I have run into the same issue. And, found out FART returns errorlevel =1 when it success and return errorlevel = 0 when it failed with "access denied" or "file not found" and etc. So, force errorlevel to 0 when it runs successfully and force it to 1 when it fails. It works for me.



回答5:

The successExitCodes list is supposed to be a list of ints. Here's a couple of suggestions:

  1. Create a small batch file that runs the executable and call your batch file (instead of fart) using the executable task.
  2. Try removing the non ints from the successExitCodes and verify what exit code fart is returning... sometimes you get unexpected return codes, like when using robocopy.


回答6:

For command line apps, you can redirect output to a file using the '>' character. A call to your app would look like:

fart.exe myfile.txt string1 string2 > myoutput.txt

Adding the redirect to your buildArgs property should do the trick.



回答7:

This line seems to work using fart:

<exec program="fart.exe" commandline="${filename} 1.0 1.1" verbose="true" failonerror="false" />

However I am not sure if the failonerror can be handled otherwise