I'm very new to VHDL and XILINX ISE. I use the version 13.2 for Xilinx ISE.
I want to design a very simple counter with the following inputs:
- Direction
- Count
The count input will be assigned to a button and I want the counter to count up or down according to direction input when the button is pressed. I have written a sample VHDL before this one. It had a clock input and It was counting according to the clock input. Now I want it to count when I press the button instead of counting synchronously.
Here's my VHDL code (please tell me if my code have a logical or any other flaw):
entity counter is
Port ( COUNT_EN : in STD_LOGIC;
DIRECTION : in STD_LOGIC;
COUNT_OUT : out STD_LOGIC_VECTOR (3 downto 0));
end counter;
architecture Behavioral of counter is
signal count_int : std_logic_vector(3 downto 0) := "0000";
begin
process
begin
if COUNT_EN='1' then
if DIRECTION='1' then
count_int <= count_int + 1;
else
count_int <= count_int - 1;
end if;
end if;
end process;
COUNT_OUT <= count_int;
end Behavioral;
I use Spartan xc3s500e and I placed the inputs accordingly. Below is my .ucf file:
#Created by Constraints Editor (xc3s500e-fg320-5) - 2013/03/18
NET "COUNT_EN" LOC = K17;
NET "COUNT_OUT[0]" LOC = F12;
NET "COUNT_OUT[1]" LOC = E12;
NET "COUNT_OUT[2]" LOC = E11;
NET "COUNT_OUT[3]" LOC = F11;
NET "DIRECTION" LOC = L13;
#Created by Constraints Editor (xc3s500e-fg320-5) - 2013/03/18
NET "COUNT_EN" CLOCK_DEDICATED_ROUTE = FALSE;
I needed to change the last line because I was getting the error:
This will not allow the use of the fast path between the IO and the Clock...
After having this error gone, I programmed the device. But the output (leds) acted crazy. They sometimes stood still for a few seconds, sometimes just flashed very fast. I could not figure out where my mistake is. I would appreciate any help, some beginner tutorials are greatly appreciated (the links i found directed me to xilinx's documentations and they seemed quite complicated for a beginner).